Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Arq. bras. oftalmol ; 78(5): 305-309, Sep.-Oct. 2015. tab, ilus
Article in English | LILACS | ID: lil-761515

ABSTRACT

ABSTRACTPurpose:To investigate the relationship between quantitative iris parameters and the presence of keratoconus.Methods:Cross-sectional observational study that included 15 affected eyes of 15 patients with keratoconus and 26 eyes of 26 normal age- and sex-matched controls. Iris parameters (area, thickness, and pupil diameter) of affected and unaffected eyes were measured under standardized light and dark conditions using anterior segment optical coherence tomography (AS-OCT). To identify optimal iris thickness cutoff points to maximize the sensitivity and specificity when discriminating keratoconus eyes from normal eyes, the analysis included the use of receiver operating characteristic (ROC) curves.Results:Iris thickness and area were lower in keratoconus eyes than in normal eyes. The mean thickness at the pupillary margin under both light and dark conditions was found to be the best parameter for discriminating normal patients from keratoconus patients. Diagnostic performance was assessed by the area under the ROC curve (AROC), which had a value of 0.8256 with 80.0% sensitivity and 84.6% specificity, using a cutoff of 0.4125 mm. The sensitivity increased to 86.7% when a cutoff of 0.4700 mm was used.Conclusions:In our sample, iris thickness was lower in keratoconus eyes than in normal eyes. These results suggest that tomographic parameters may provide novel adjunct approaches for keratoconus screening.


RESUMOObjetivo:Investigar a relação entre os parâmetros quantitativos irianos e a presença de ceratocone.Métodos:Estudo observacional transversal com quinze olhos de 15 pacientes com ceratocone e 26 olhos de 26 indivíduos normais, pareados por idade e gênero. Parâmetros da íris (área, espessura e diâmetro da pupila) de olhos com ceratocone e olhos sem ceratocone foram medidos usando tomografia de coerência óptica do segmento anterior (AS-OCT), em condições padronizadas de alta luminosidade e ambiente escuro. Com o objetivo de maximizar a sensibilidade, especificidade e identificar o melhor ponto de corte na diferenciação entre ceratocone e indivíduos normais, foi realizada a análise quantitativa da curva característica operacional do receptor (ROC) dos parâmetros de espessura da íris.Resultados:A área e espessura da íris estavam reduzidas nos olhos de pacientes com ceratocone. Observamos que o melhor parâmetro para discriminar indivíduos normais de pacientes com ceratocone foi a espessura média na margem pupilar, tanto em condições de alta luminosidade quanto em ambiente escuro. O desempenho diagnóstico deste parâmetro foi avaliado pela análise quantitativa da área sob a curva ROC (AROC), mostrando AROC de 0,8256, com sensibilidade de 80,0% e especificidade de 84,6% usando um ponto de corte de 0,4125 milímetros de espessura da íris. A sensibilidade aumentou para 86,7%, com um corte de 0,4700 milímetros de espessura da íris.Conclusões:Na amostra deste estudo, a espessura da íris demostrou-se reduzida nos olhos com ceratocone. Estes resultados sugerem que os parâmetros tomográficos podem proporcionar novas informações no auxilio da triagem de pacientes com ceratocone.


Subject(s)
Adolescent , Adult , Female , Humans , Male , Middle Aged , Young Adult , Iris/pathology , Keratoconus/pathology , Tomography, Optical Coherence , Cornea/pathology , Darkness , Epidemiologic Methods , Iris/physiopathology , Keratoconus/physiopathology , Lightning , Reference Values , Visual Acuity
2.
Arq. bras. oftalmol ; 71(6): 793-798, nov.-dez. 2008. ilus, tab
Article in English | LILACS | ID: lil-503441

ABSTRACT

PURPOSE: To compare morphometric features between fellow acute primary angle-closure (APAC) eyes and glaucomatous or suspect eyes with narrow angle (NA). METHODS: Fellow eyes of 30 patients with unilateral APAC and 30 with NA were evaluated by ultrasound biomicroscopy (UBM) under light and dark conditions. UBM parameters such as anterior chamber depth (ACD), angle opening distance at 250 µm/500 µm from the scleral spur (AOD250/AOD500), trabecular ciliary process distance (TCPD) and iris-lens contact distance (ILCD) were measured in the superior (SQ) and inferior (IQ) quadrants. RESULTS: Significant differences between APAC fellow and NA eyes were found in ACD, P<0.001; AOD250 at SQ and IQ, P<0.001; AOD500 at SQ and IQ, P<0.001; TCPD light, P=0.010 and TCPD dark at SQ, P=0.031; and TCPD light at IQ, P=0.010. Significant differences between light and dark examinations of APAC fellow eyes were found in ILCD (P=0.009) at SQ and ILCD at IQ (P=0.006), and of NA eyes in ILCD at SQ (P=0.047) and ILCD at IQ (P<0.001). CONCLUSIONS: APAC fellow eyes have a more crowded anterior segment and shallower ACD than NA eyes. ILCD decreases in both groups when the illumination conditions change from light to dark.


OBJETIVO: Comparar características morfométricas entre olhos contralaterais com fechamento angular primário agudo (FAPA) e olhos glaucomatosos ou suspeitos com ângulo estreito (AE). MÉTODOS: Olhos contralaterais de 30 pacientes com FAPA unilateral e olhos de 30 pacientes com AE foram avaliados através da biomicroscopia ultra-sônica (BUS) no claro e escuro. Parâmetros da BUS como a profundidade central de câmara anterior (PCA), distância da abertura angular a 250 µm/500 µm do esporão escleral (AOD250/AOD500), distância entre o processo ciliar e o trabeculado (TCPD) e distância do contato iris-cristalino (ILCD) foram medidos nos quadrantes superior (QS) e inferior (QI). RESULTADOS: Diferenças significativas entre olhos contralaterais de FAPA e olhos com AE foram encontradas na PCA, p<0,001; AOD250 no QS e QI, p<0,001; AOD500 no QS e QI, p<0,001; TCPD no claro, p=0,010 e TCPD no escuro no QS, p=0,031; e TCPD no claro no QI, p=0,010. Diferenças significativas entre exames no claro e escuro realizados em olhos contralaterais com FAPA foram encontradas na ILCD (p=0,009) no QS e ILCD no QI (p=0,006), e em olhos com SE na ILCD no QS (p=0,047) e ILCD no QI (p<0,001). CONCLUSÕES: Olhos contralaterais de FAPA apresentam um segmento anterior mais aglomerado e uma PCA menor que olhos com AE. ILCD diminui em ambos os grupos quando as condições de iluminação mudam do claro para o escuro.


Subject(s)
Aged , Female , Humans , Male , Middle Aged , Adaptation, Ocular/physiology , Anterior Eye Segment , Glaucoma, Angle-Closure , Acute Disease , Anterior Chamber/physiopathology , Anterior Chamber , Anterior Eye Segment/physiopathology , Chi-Square Distribution , Dark Adaptation/physiology , Gonioscopy , Glaucoma, Angle-Closure/physiopathology , Intraocular Pressure , Iris/physiopathology , Iris , Microscopy, Acoustic , Prospective Studies , Sclera/physiopathology , Sclera
3.
Belo Horizonte; s.n; 1998. 170 p. tab, graf.
Thesis in Portuguese | LILACS | ID: lil-247686

ABSTRACT

Em nosso estudo, realizou-se a avaliaçäo funcional da inervaçäo autonômica da íris de portadores das várias formas de manifestaçäo clínica da hanseníase através da medida do tempo do ciclo pupilar. Concomitantemente, procurou-se pesquisar a funçäo lacrimal, o comportamento da pressäo arterial diante das variaçöes posturais, as alteraçöes da temperatura corporal e a ocorrência de sintomas relacionados com o comprometimento do sistema nervoso autônomo. Foram incluídos 81 participantes, divididos em dois grupos: o Grupo I, composto por 63 portadores de hanseníase, e estratificado em cinco subgrupos (HT, HB, HBB, HBL e HL), dependendo da forma de manifestaçäo clínica da doença, e o Grupo II ou grupo controle, composto por 18 indivíduos hígidos. Limitamos a idade de todos os participantes entre 16 e 45 anos. Os portadores de hanseníase estavam em tratamento regular, tinham o tempo de diagnóstico inferior a 3 anos, grau de incapacidade 0 ou 1 e näo apresentavam surto reacional no momento da avaliaçäo. A medida do tempo do ciclo pupilar, realizada segundo a padronizaçäo de Miller & Thompson (1978), demonstrou ser um método ambulatorial näo invasivo, simples e objetivo para a avaliaçäo funcional da inervaçäo autonômica da íris. O tempo do ciclo pupilar observado nos integrantes dos Subgrupos HT e HBT foi estatisticamente semelhante ao dos indivíduos hígidos enquanto o tempo do ciclo pupilar dos integrantes dos Subgrupos HBB, HBL e HL apresentou um prolongamento significativo. Dentre os outros sinais disautonômicos pesquisados, apenas a frequência de disfunçäo lacrimal nos portadores das formas HBT e HL foi significativamente maior em relaçäo à dos indivíduos hígidos. Näo se verificou a ocorrência de hipotensäo arterial ortostática e nem de alteraçöes da temperatura corporal nos portadores de hanseníase. No entanto, a frequência de alguns sintomas disautonômicos foi significativamente aumentada no Grupo I em relaçäo ao Grupo II; esses sintomas foram mais frequentes no Subgrupo HL e menos no Subgrupo HT.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Middle Aged , Pupil Disorders/physiopathology , Leprosy/complications , Iris/physiopathology , Academic Dissertation , Autonomic Nervous System Diseases/complications , Iris/innervation , Reflex, Pupillary/physiology
4.
Acta pediátr. Méx ; 16(3): 109-12, mayo-jun. 1995. ilus, tab
Article in Spanish | LILACS | ID: lil-173796

ABSTRACT

Se revisaron retrospectivamente los expedientes de pacientes con el síndrome de Waardenburg, entre mayo de 1988 y febero de 1993, se buscó el grado de hipoacusia como característica clínica del síndrome y el tipo del mismo. En la literatura, la hipoacusia varía en frecuencia y grado, nosotros observamos que es la principal manifestación clínica, con una frecuencia significativamente más alta (86.60 por ciento), debiéndose considerar como primordial para el consejo genético en las familias afectadas por el síndrome de Waardenburg


Subject(s)
Infant , Child, Preschool , Child , Humans , Male , Female , Genetic Counseling/supply & distribution , Deafness/physiopathology , Iris/physiopathology , Hearing Loss, Bilateral/diagnosis , Skin Pigmentation/genetics , Waardenburg Syndrome/physiopathology , Acoustic Impedance Tests/methods , Auditory Perceptual Disorders/physiopathology
5.
SJO-Saudi Journal of Ophthalmology. 1994; 8 (4): 202
in English | IMEMR | ID: emr-35416
SELECTION OF CITATIONS
SEARCH DETAIL